Corundum, bubble-alumina, high-alumina and clay-based options provide different density and service-temperature ranges. Specify the furnace zone and exposure rather than treating the grades as interchangeable.
Typical applications
- Reformers, ethylene cracking furnaces and carbon-black furnaces
- Gasification and other petrochemical furnace lining zones

Technical specifications
| Product family | Corundum wear-resistant castables | Alumina bubble castables | High-alumina castables | Clay-based castables | ||||
|---|---|---|---|---|---|---|---|---|
| Grade | CC-32 | CC-31 | AC-1.4 | AC-1.6 | LC-2.4 | LC-2.5 | NC-2.2 | |
| Al₂O₃ (%, ≥) | 98 | 96 | 92 | 94 | 60 | 75 | 40 | |
| CaO (%, ≥; inequality retained as published) | 0.5 | 1.0 | 1.0 | 0.5 | 1.8 | 2.5 | 4.2 | |
| Bulk density (g/cm³) | 110℃×24h | 3.2 | 3.1 | 1.4 | 1.6 | 2.4 | 2.5 | 2.3 |
| 1450℃×4h | 3.15 | 3.05 | 1.3 | 1.5 | 2.30 | 2.40 | 2.10 | |
| Compressive strength (MPa) | 110℃×24h | 32 | 26 | 12 | 14 | 60 | 70 | 75 |
| 1450℃×4h | 45 | 55 | 24 | 30 | 85 | 93 | 98 | |
| Flexural strength (MPa) | 110℃×24h | 6 | 5 | 1.5 | 2.5 | 8 | 10 | 11 |
| 1450℃×4h | 10 | 8 | 4 | 7 | — | 12 | 14 | |
| Permanent linear change after heating (%) | 1000℃×4h | — | — | — | — | ±0.2 | — | ±0.5 |
| 1500℃×4h | ±0.2 | ±0.3 | ±0.5 | ±0.5 | — | ±0.5 | — | |
| Mixing water (%) | 5-5.5 | 5.5-6 | 12-15 | 11-14 | 6-8 | 6.5-7.5 | 7-8 | |
| Maximum service temperature (°C) | 1600 | 1500 | 1500 | 1500 | 1350 | 1400 | 1200 | |
Data clarification
Published reference figures are not a certified specification for the quoted batch. Confirm the grade, test method, furnace conditions and acceptance requirements before ordering. A dash means no value was stated; classification temperature is not a continuous-service guarantee.
- The CaO row is marked ≥ in the reference. This inequality has not been changed to a presumed maximum.
- NC-2.2 has a dried bulk density of 2.3 in the table; the grade name has not been used to overwrite it. Missing flexural-strength and linear-change cells remain unfilled.
Information for quotation
Send the product or grade, furnace zone, operating temperature and atmosphere, dimensions or lining drawing, quantity and delivery destination.